Home / Wiki / Electronics / High voltage electrical system
Electronics · canonical reference

High voltage electrical system

The conversion is based on a Nissan Leaf drivetrain, with selected subsystems replaced by custom or Mitsubishi components.

In a more modern EV there are usually several loads driven by the high voltage system — AC compressor, electrical heater and so on. In the Aphid there are two consumers: the Mitsubishi Outlander OBC/DC-DC and the traction inverter.

The pack itself is described under Batteries and is gated by the Main contactors and precharge.

Battery string and fusing

The front and rear battery sections are connected in series to form a 96s2p traction pack. The MSD in the front battery contains the traction pack’s 250 A main fuse. It sits on the front pack’s negative leg, between the negative contactor and the pack terminal.

The MSD part is not chosen. The candidate is the Amphenol MINI-MSD. Facts from Amphenol drawing MINIMSD, revision B:

  • The plug holds the fuse. MINI-MSDM250 has a 250 A Bussmann fuse and MINI-MSDM2501 a 250 A Zhongrong fuse.
  • The receptacle is MINI-MSDF000F for front mounting or MINI-MSDF000R for rear mounting. It has two M6 studs, tightened to 5.3 Nm.
  • The receptacle has a two-way interlock connector, MSD-HVIL-2S.
  • The rated voltage is 690 V AC with the Bussmann fuse and 750 V DC with the Zhongrong fuse. The drawing gives no DC rating for the Bussmann fuse.
  • The ambient temperature range is -40 °C to 70 °C, and the mated pair is sealed to IP67 and IP6K9K.

The HV junction box distributes the completed battery string to the inverter and OBC/DC-DC. The OBC/DC-DC branch has its own 30 A fuse on the positive leg in the junction box, the rating Mitsubishi uses for the unit, and runs in 6 mm² cable. The fuse type remains to be selected. The branch has no contactor of its own, so the whole HV bus, inverter included, is live while the car charges.

Isolation

The traction HV system is floating, with no on-board isolation monitor. Safety architecture > electrical-safety covers isolation testing and the HV interlock loop.

Electrical diagram

The schematic follows the HV bus from the battery string through the junction box to the inverter, motor and OBC/DC-DC. The MSD is inside the front battery; see Batteries. The interlock loop runs along the bottom.

HV System Overview Primary fuse box INTLK Front Battery HV- hv:2 HV+ hv:1 INTLK IN bms_signals:6 SAFE PWR bms_signals:3 INTLK OUT bms_signals:7 Rear Battery HV- hv:2 HV+ hv:1 INTLK IN bms_signals:6 SAFE PWR bms_signals:3 INTLK OUT bms_signals:7 HV Junction Box PACK HV+ pack:1 PACK HV- pack:2 INV DC+ inverter:1 INV DC- inverter:2 OBC DC+ obc:1 OBC DC- obc:2 INTLK IN intlk:1 INTLK OUT intlk:2 Inverter DC+ hv:1 DC- hv:2 U phases:1 V phases:2 W phases:3 INTLK IN INTLK OUT OBC/DC-DC DC+ hv:2 DC- hv:1 Motor U power:1 V power:2 W power:3 E-Stop INTLK OUT INTLK IN VCM SAFE PWR INTLK OG OG OG OG OG OG OG OG OG OG GN GN GN GN GN RD RD GN
HV system overview

The cable drawings are on the HV cables page.

Linked from the build log 4 posts reference this page