The original plan used a Nissan Leaf power delivery module, but it does not fit the available space. Charging and low-voltage conversion therefore use a more easily packaged combined on-board charger (OBC) and DC-DC converter from a Mitsubishi Outlander PHEV. The OBC charges the traction battery from single-phase AC. The DC-DC converter supplies the 12 V system and maintains the auxiliary battery. The VCM controls the unit over CAN1 and two discrete signals.
Facts about the unit from the sources listed under sources:
| Property | Value |
|---|---|
| Charger output | 3.3 kW, at most 12 A DC |
| AC input | Single phase, about 14.5 A at full power |
| DC-DC output | 1.8 kW at about 14.4 V, about 125 A |
| HV bus range | 200 V to 400 V |
| Size and weight | 370 x 270 x 150 mm, about 12 kg |
| Cooling | Liquid |
The traction pack stays below 400 V, which is where the unit stops working. Requesting more than 12 A makes the charger refuse to start.
Connectors
The pin numbers come from the Mitsubishi circuit diagrams, which name the connectors H-108, H-101, D-205 and D-208.
HV connector
Two pins: pin 1 is negative and pin 2 is positive. The connector has no interlock contacts, so the unit is excluded from the HV interlock loop.
The unit has its own fused branch from the HV junction box, described under HV system. The branch has a 30 A fuse, the rating Mitsubishi uses, and 6 mm² cable. The charger draws at most 12 A and the DC-DC about 9 A at the lowest bus voltage, so the two together stay near 21 A.
The unit has no contactor of its own, so its input capacitors charge together with the inverter’s during precharge. The VCM keeps the DC-DC disabled until precharge is complete. A running DC-DC would draw its load through the precharge resistor and the bus would never reach pack voltage.
AC connector
A five-way housing, Yazaki 7283-7350-30, with three cavities used.
| Pin | Signal |
|---|---|
| 1 | Neutral |
| 2 | Line |
| 4 | Protective earth |
Mitsubishi screens the line and neutral conductors and earths the screens to the body.
12 V output
A single M8 stud carries the positive output. The return is the aluminium case, so the case needs a ground strap as heavy as the output cable. The output cable is 35 mm² behind a 150 A MIDI fuse in the primary distribution box, sized for the full 125 A. See Low voltage electrical system > primary-distribution.
Signal connector
A 13-way connector on a short tail. The mating half is Sumitomo 6189-1092.
| Pin | Signal | Connects to |
|---|---|---|
| 4 | DC SW, DC-DC enable | VCM output |
| 5 | CHIN | Not used |
| 6 | CAN H | CAN1 |
| 7 | Sense | Always-on 12 V, 7.5 A fuse |
| 8 | IGCT, main 12 V supply | EV relay |
| 9 | Control pilot | Charge inlet CP |
| 10 | Ground | Ground stud |
| 12 | CHOT | Not used |
| 13 | CAN L | CAN1 |
Pins 1, 2, 3 and 11 are empty. CHIN and CHOT are a serial link to Mitsubishi’s remote-control unit.
A note on the openinverter wiki says the numbers moulded on the connector are reversed. The Mitsubishi diagram agrees with the table above. Check the wire colours on the unit’s tail before crimping: grey DC SW, black CAN H, green sense, yellow IGCT, white control pilot, black ground and red CAN L.
Supply and wake-up
The sense input is always live. IGCT is fed from the EV relay in the rear EV distribution box, which the VCM pulls in for driving and for charging. The unit only charges with IGCT powered. The control pilot alone does not wake it, and builders on the openinverter forum report faults when IGCT is powered permanently.
The EV relay also feeds the inverter’s ignition input, so the inverter is awake while the car charges.
The current the sense input draws while the car sleeps is not documented. Measure it on the bench.
CAN interface
The unit is an unterminated intermediate node on CAN1, between the VCM and the inverter, at 500 kbit/s. It has no termination resistor. See Nissan Leaf EV-CAN > vehicle-buses.
DC-DC
The Mitsubishi DC-DC converter maintains the auxiliary 12 V battery and supplies the 12 V system whenever the HV system is active, in a similar fashion to the alternator of a car with a combustion engine. It needs 12 V on sense and IGCT, then 12 V on DC SW. It runs without any CAN message.
Cooling
The unit is liquid cooled. The coolant runs through the radiator, the OBC, the inverter and the motor in series, and the pump runs while the car charges. The OBC sits first after the radiator, where the coolant is coldest. The pump relay shares the EV relay’s control line, so the pump has power whenever IGCT has.
The port size and the flow the unit needs are not documented in the sources. Check that its ports do not restrict the flow to the inverter and motor.
Charge inlet
The inlet is a BESEN BS-EVSC004 Type 2 inlet, rated 32 A, ordered with 16 A single-phase tails of 2.5 mm². L1, neutral and protective earth connect to the OBC. L2 and L3 are unused.
- The control pilot (CP) runs straight to pin 9 of the OBC signal connector. The OBC holds the pilot resistors, signals the charging point that it is ready, and limits its current to what the charging point advertises.
- The proximity pilot (PP) connects to the VCM. The OBC has no PP input. PP tells the VCM that a cable is plugged in, wakes it from sleep and blocks driving. The resistance from PP to earth also gives the cable’s current rating.
Status LEDs
The inlet has a red and a green lens with room for an LED behind each, but no LEDs. Two 12 V indicator LEDs are fitted, each on its own VCM output, with a shared return to the VCM.
| LED | Meaning |
|---|---|
| Green, pulsing | Charging |
| Green, steady | Charged |
| Red | Fault |
Lock
A Type 2 plug has no latch, so only friction holds it in the inlet. The BESEN BS-EL0003 lock drives a bolt into the plug. The lock is designed in but optional: the car charges without it.
| Property | Value |
|---|---|
| Supply | 12 V DC, 10.5 V to 13.5 V |
| Current | 650 mA maximum |
| Drive | +12 V on the red lead locks, reversed polarity unlocks |
| Pulse | 0.2 s to 1 s, never longer than 3 s |
| Feedback | Switch between the white and blue leads, closed while locked |
| Tail | 500 mm, four wires of 24 AWG |
The bolt stays in place without power. The VCM drives the motor from an H-bridge and reads the feedback switch on one input. It unlocks the inlet when the charge is finished, before it goes to sleep, so the cable comes out without the key. A stop button beside the inlet ends a charge early and unlocks. The lock’s manual release covers a flat 12 V battery.
The charge sequence is described under operating states.
Charge wiring
The harness drawings are on the Rear loom page for the signal leads and the HV cables page for the AC lead.
Sources
- Mitsubishi Outlander PHEV service manual, circuit diagrams HKAE0E05AC00ENG, HKAE0E05BC00ENG, HKAE0E05CC00ENG and HKAE0E06AC00ENG: connector pin numbers, fuses and the pilot wiring.
- openinverter wiki, Mitsubishi Outlander DCDC OBC: ratings, connector part numbers, wire colours and CAN messages. It links to the circuit diagrams.
- openinverter forum, Outlander charger thread: IGCT behaviour, voltage limits, cooling and case grounding, as reported by builders.
- BESEN datasheet for the BS-EL0003 lock and the evshop.eu listings for the inlet and the lock.