The main contactors keep the HV system de-energised whenever the car is not in use. They are part of the Safety architecture concept and the last resort for bringing the system into a safe state.
This page specifies how the contactors are closed and opened, and what each unit does in between. The fault reactions are on the safety page.
Main contactors
Each of the Batteries has a positive and a negative main contactor, all Littelfuse DCNHE250MFA-B units. The string runs from the pack negative through the MSD, the front negative contactor, the front cell stack, the front positive contactor, the series link, the rear negative contactor, the rear cell stack and the rear positive contactor to the pack positive.
The contactors have mechanically linked auxiliary contacts. They are not wired. Welded contactors are found from the BMS voltage measurements instead, so any contactor can be used, with or without auxiliary contacts.
Precharge
Precharge is a Littelfuse DCNSEV30-B in series with a 10 Ω 100 W power
resistor, connected in parallel with the positive main contactor in the
front battery.
The DC-link capacitance of the inverter and the OBC/DC-DC is not known yet. It will be measured. The precharge timeouts below are provisional until then.
Who does what
Every contactor coil has two switches in series. Both have to be on for the contactor to close.
| Unit | Switches | Decides |
|---|---|---|
| VCM main processor | Nothing directly | Everything: when to close and open, precharge, welded-contactor checks and the reaction to faults. |
| VCM monitor processor | The high-side supply to every coil, called safe power | Only when to cut safe power, as described under VCM monitor firmware. |
| Front and rear BMS | The low side of each coil in its pack | Nothing about the sequence. It drives its outputs as the VCM commands, and opens them on its own only for the reasons under bms-rules. |
The BMS is responsible for its cells. It estimates the state of charge, reports the current the pack can take in and give out, and acts when a cell or the current goes outside its limits. See cell protection.
The VCM main processor also reads the HV interlock loop on its own input, so it can react to an open loop without waiting for the monitor.
Voltage measurements
Each BMS measures two voltages in its pack and reports both on CAN2:
V_stack, across the cell stack, inside the contactors. The BMS checks it against the sum of its cell voltages.V_out, across the pack’s two HV terminals, outside both main contactors. With either contactor open, the sense divider pulls it to about 0 V.
The front BMS also measures the string current on the shunt. The rear BMS has no shunt and takes the current from the front BMS’s CAN2 message.
The Nissan Leaf traction inverter reports the DC-link voltage V_link on CAN1. Once the
contactors are closed, V_link equals V_out of the front pack plus V_out
of the rear pack.
CAN2 traffic
The CAN2 message crate defines the frames. This page sets what they carry and how often.
| Message | From | Period | Content |
|---|---|---|---|
| Contactor command | VCM, one per BMS | 10 ms | One bit per output: negative, positive and, for the front BMS, precharge. A fault clear bit. Alive counter and CRC. |
| Fast status | Each BMS | 10 ms | Output states, safe power seen, V_stack, V_out, string current from the front BMS, open request and trip reason. Alive counter and CRC. |
| Pack status | Each BMS | 100 ms | State of charge, allowed charge and discharge current, minimum and maximum cell voltage and temperature. |
A receiver treats a frame with a wrong CRC, or with the same alive counter as the previous frame, as missing. Both directions time out after 100 ms, which is ten missed frames.
BMS rules
The BMS follows the contactor command, with four exceptions:
- Command lost. No valid command for 100 ms. The BMS opens all its outputs and blocks.
- Safe power lost. Safe power drops while an output is on. The BMS switches all its outputs off and blocks. A coil without its high side has already released, but switching the low side off keeps the contactor from closing again when safe power returns.
- Cell protection. The BMS opens its outputs and trips on the limits under Safety architecture > cell-protection.
- Blocked. A blocked BMS ignores close bits until it has received a command with every output open. It then follows the command again. This keeps a contactor from closing without precharge when the bus or safe power comes back.
Safe power present with no output commanded on is normal between the monitor enabling safe power and the first close command, and after a controlled open. The BMS only reports it. The VCM uses that report to check the high-side switch.
A BMS wakes on CAN2 traffic. It goes back to sleep when it has had no CAN2 traffic for 5 s and all its outputs are off. It may stay awake longer to finish cell balancing.
stateDiagram-v2
[*] --> Sleep
Sleep --> Following: CAN2 traffic
Following --> Sleep: No CAN2 traffic for 5 s, outputs off
Following --> Blocked: Command lost for 100 ms, or safe power lost
Blocked --> Following: Command with every output open
Following --> Tripped: Cell protection limit
Blocked --> Tripped: Cell protection limit
Tripped --> Following: Fault clear with every output open, cause gone
Following drives the outputs as commanded. Blocked and Tripped hold
every output off.
VCM contactor states
The VCM main processor runs the sequence. Every step has a timeout, and
every timeout or failed check goes to Fault.
stateDiagram-v2
[*] --> Waking: Key or charge cable
Waking --> Open: Both BMS reporting, checks pass
Open --> Enabling: Close requested
Enabling --> WeldCheck: Both BMS see safe power
WeldCheck --> Precharging: No welded contactor
Precharging --> Closing: Precharge complete
Closing --> Closed: Front positive closed, precharge open
Closed --> Opening: Key off or end of charge
Opening --> Open: Current below 5 A or 1 s
Open --> [*]: Monitor released, VCM sleeps
Enabling --> Fault
WeldCheck --> Fault
Precharging --> Fault
Closing --> Fault
Closed --> Fault
Fault --> [*]: Next key cycle
Waking
The VCM starts sending contactor commands with every output open as soon as it wakes. That traffic wakes both BMS controllers. Both have to send valid fast status within 500 ms. Then the VCM checks:
- Neither BMS reports a trip or an open request.
- Neither BMS sees safe power. Safe power present before the monitor has enabled it means a stuck high-side switch, which the monitor could not cut.
V_outis below 20 V on both packs. A higher voltage with every contactor open means both contactors of that pack have welded.V_stackof each pack agrees with the sum of its cells within 2 %.
Closing
The car closes the contactors the same way for driving and for charging. Each step waits for the measurements to settle before it checks them.
- Enable safe power. The VCM asks the monitor to enable safe power. Both BMS have to report safe power within 100 ms.
- Check the positive contactors. The VCM closes the negative contactor
of both packs alone. After 100 ms,
V_outof each pack has to be below 20 V. A higher voltage means that pack’s positive contactor has welded. On the front pack it can also be the precharge contactor. The VCM then opens both. - Check the negative contactors. The VCM closes the positive contactor
of both packs alone, with the same check after 100 ms. A voltage now
means the negative contactor has welded. The VCM then opens both.
Both packs are checked at the same time. With one contactor of each pack
closed there is still no closed circuit, so the sense dividers hold
V_outnear 0 V unless a contactor has welded. - Close everything but the front positive. The VCM closes the rear
negative, the rear positive and the front negative. After 50 ms,
V_outof the rear pack has to be within 5 V of itsV_stack. - Precharge. The VCM closes the precharge contactor. Current flows
through the resistor into the DC link, and
V_outof the front pack rises toward itsV_stack. - Close the front positive. The VCM closes it, waits 50 ms, opens
the precharge contactor and waits another 50 ms.
V_outof the front pack then has to be within 5 V of itsV_stack.
Precharge is complete when both hold:
V_stackminusV_outof the front pack is below 10 V, which means less than 1 A through the 10 Ω resistor.V_linkfrom the inverter is within 15 V of the front and rearV_outadded together.
Precharge has failed when either holds:
V_outof the front pack is below 50 % of itsV_stack100 ms after the precharge contactor closed. A short on the HV bus puts about 40 A, or 16 kW, into the resistor, so this check cuts it short.- Precharge is not complete within 500 ms.
After a failed precharge the VCM opens everything. It tries again after
30 s, at most twice. A third failure latches Fault until the next key
cycle.
sequenceDiagram
participant M as VCM main
participant S as VCM monitor
participant F as Front BMS
participant R as Rear BMS
participant I as Inverter
M->>F: Command all open
M->>R: Command all open
F-->>M: Fast status, no safe power, V_out below 20 V
R-->>M: Fast status, no safe power, V_out below 20 V
M->>S: Enable safe power
S-->>F: Safe power on
S-->>R: Safe power on
F-->>M: Safe power seen
R-->>M: Safe power seen
M->>F: Close negative only
M->>R: Close negative only
F-->>M: V_out below 20 V after 100 ms
R-->>M: V_out below 20 V after 100 ms
M->>F: Close positive only
M->>R: Close positive only
F-->>M: V_out below 20 V after 100 ms
R-->>M: V_out below 20 V after 100 ms
M->>R: Close negative and positive
M->>F: Close negative
R-->>M: V_out matches V_stack
M->>F: Close negative and precharge
loop Every 10 ms, at most 500 ms
F-->>M: V_stack, V_out
I-->>M: V_link on CAN1
end
M->>F: Close negative, precharge and positive
M->>F: Close negative and positive, 50 ms later
F-->>M: V_out matches V_stack
Opening
A controlled open is used for key off, the end of a charge and the faults the fault table marks as controlled.
- The VCM commands zero torque from the inverter and zero current from the OBC.
- It waits until the string current is below 5 A, or at most 1 s.
- It commands every output open on both BMS in the same frame.
- For a key off or the end of a charge, it asks the monitor to release safe power. Both BMS have to report safe power gone within 100 ms. Otherwise the high-side switch is stuck on, which is a fault.
An immediate open skips step 2. The VCM commands every output open in the next frame, whatever the current.
The weld checks run only while closing. After an open, the DC link stays
charged until the inverter discharges it, and both V_out dividers sit in
series across it, so V_out is not 0 V.
sequenceDiagram
participant M as VCM main
participant I as Inverter and OBC
participant F as Front BMS
participant R as Rear BMS
participant S as VCM monitor
M->>I: Zero torque, zero charge current
loop Until the current is below 5 A, at most 1 s
F-->>M: String current
end
M->>F: Command all open
M->>R: Command all open
M->>S: Release safe power
S-->>F: Safe power off
S-->>R: Safe power off
F-->>M: Safe power gone
R-->>M: Safe power gone
Measurement disagreement
While the contactors are closed, the VCM compares V_link with the front
and rear V_out added together. A difference above 20 V for 1 s
means one of the measurements is wrong. The VCM records a fault and keeps
the contactors closed, so the car does not lose drive. It refuses the next
close until the fault is cleared on a key cycle.
During precharge the same comparison, with the 15 V limit, is part of the completion check. A disagreement there keeps the front positive open and ends as a failed precharge.
Drawings
The battery schematics show the contactors, their coil wiring and the voltage sense leads. The interlock and safe power schematic shows the coil supply from the VCM.