Home / Wiki / Electronics / Main contactors and precharge
Electronics · canonical reference

Main contactors and precharge

The main contactors keep the HV system de-energised whenever the car is not in use. They are part of the Safety architecture concept and the last resort for bringing the system into a safe state.

This page specifies how the contactors are closed and opened, and what each unit does in between. The fault reactions are on the safety page.

Main contactors

Each of the Batteries has a positive and a negative main contactor, all Littelfuse DCNHE250MFA-B units. The string runs from the pack negative through the MSD, the front negative contactor, the front cell stack, the front positive contactor, the series link, the rear negative contactor, the rear cell stack and the rear positive contactor to the pack positive.

The contactors have mechanically linked auxiliary contacts. They are not wired. Welded contactors are found from the BMS voltage measurements instead, so any contactor can be used, with or without auxiliary contacts.

Precharge

Precharge is a Littelfuse DCNSEV30-B in series with a 10 Ω 100 W power resistor, connected in parallel with the positive main contactor in the front battery.

The DC-link capacitance of the inverter and the OBC/DC-DC is not known yet. It will be measured. The precharge timeouts below are provisional until then.

Who does what

Every contactor coil has two switches in series. Both have to be on for the contactor to close.

UnitSwitchesDecides
VCM main processorNothing directlyEverything: when to close and open, precharge, welded-contactor checks and the reaction to faults.
VCM monitor processorThe high-side supply to every coil, called safe powerOnly when to cut safe power, as described under VCM monitor firmware.
Front and rear BMSThe low side of each coil in its packNothing about the sequence. It drives its outputs as the VCM commands, and opens them on its own only for the reasons under bms-rules.

The BMS is responsible for its cells. It estimates the state of charge, reports the current the pack can take in and give out, and acts when a cell or the current goes outside its limits. See cell protection.

The VCM main processor also reads the HV interlock loop on its own input, so it can react to an open loop without waiting for the monitor.

Voltage measurements

Each BMS measures two voltages in its pack and reports both on CAN2:

  • V_stack, across the cell stack, inside the contactors. The BMS checks it against the sum of its cell voltages.
  • V_out, across the pack’s two HV terminals, outside both main contactors. With either contactor open, the sense divider pulls it to about 0 V.

The front BMS also measures the string current on the shunt. The rear BMS has no shunt and takes the current from the front BMS’s CAN2 message.

The Nissan Leaf traction inverter reports the DC-link voltage V_link on CAN1. Once the contactors are closed, V_link equals V_out of the front pack plus V_out of the rear pack.

CAN2 traffic

The CAN2 message crate defines the frames. This page sets what they carry and how often.

MessageFromPeriodContent
Contactor commandVCM, one per BMS10 msOne bit per output: negative, positive and, for the front BMS, precharge. A fault clear bit. Alive counter and CRC.
Fast statusEach BMS10 msOutput states, safe power seen, V_stack, V_out, string current from the front BMS, open request and trip reason. Alive counter and CRC.
Pack statusEach BMS100 msState of charge, allowed charge and discharge current, minimum and maximum cell voltage and temperature.

A receiver treats a frame with a wrong CRC, or with the same alive counter as the previous frame, as missing. Both directions time out after 100 ms, which is ten missed frames.

BMS rules

The BMS follows the contactor command, with four exceptions:

  1. Command lost. No valid command for 100 ms. The BMS opens all its outputs and blocks.
  2. Safe power lost. Safe power drops while an output is on. The BMS switches all its outputs off and blocks. A coil without its high side has already released, but switching the low side off keeps the contactor from closing again when safe power returns.
  3. Cell protection. The BMS opens its outputs and trips on the limits under Safety architecture > cell-protection.
  4. Blocked. A blocked BMS ignores close bits until it has received a command with every output open. It then follows the command again. This keeps a contactor from closing without precharge when the bus or safe power comes back.

Safe power present with no output commanded on is normal between the monitor enabling safe power and the first close command, and after a controlled open. The BMS only reports it. The VCM uses that report to check the high-side switch.

A BMS wakes on CAN2 traffic. It goes back to sleep when it has had no CAN2 traffic for 5 s and all its outputs are off. It may stay awake longer to finish cell balancing.

stateDiagram-v2
    [*] --> Sleep
    Sleep --> Following: CAN2 traffic
    Following --> Sleep: No CAN2 traffic for 5 s, outputs off
    Following --> Blocked: Command lost for 100 ms, or safe power lost
    Blocked --> Following: Command with every output open
    Following --> Tripped: Cell protection limit
    Blocked --> Tripped: Cell protection limit
    Tripped --> Following: Fault clear with every output open, cause gone

Following drives the outputs as commanded. Blocked and Tripped hold every output off.

VCM contactor states

The VCM main processor runs the sequence. Every step has a timeout, and every timeout or failed check goes to Fault.

stateDiagram-v2
    [*] --> Waking: Key or charge cable
    Waking --> Open: Both BMS reporting, checks pass
    Open --> Enabling: Close requested
    Enabling --> WeldCheck: Both BMS see safe power
    WeldCheck --> Precharging: No welded contactor
    Precharging --> Closing: Precharge complete
    Closing --> Closed: Front positive closed, precharge open
    Closed --> Opening: Key off or end of charge
    Opening --> Open: Current below 5 A or 1 s
    Open --> [*]: Monitor released, VCM sleeps
    Enabling --> Fault
    WeldCheck --> Fault
    Precharging --> Fault
    Closing --> Fault
    Closed --> Fault
    Fault --> [*]: Next key cycle

Waking

The VCM starts sending contactor commands with every output open as soon as it wakes. That traffic wakes both BMS controllers. Both have to send valid fast status within 500 ms. Then the VCM checks:

  • Neither BMS reports a trip or an open request.
  • Neither BMS sees safe power. Safe power present before the monitor has enabled it means a stuck high-side switch, which the monitor could not cut.
  • V_out is below 20 V on both packs. A higher voltage with every contactor open means both contactors of that pack have welded.
  • V_stack of each pack agrees with the sum of its cells within 2 %.

Closing

The car closes the contactors the same way for driving and for charging. Each step waits for the measurements to settle before it checks them.

  1. Enable safe power. The VCM asks the monitor to enable safe power. Both BMS have to report safe power within 100 ms.
  2. Check the positive contactors. The VCM closes the negative contactor of both packs alone. After 100 ms, V_out of each pack has to be below 20 V. A higher voltage means that pack’s positive contactor has welded. On the front pack it can also be the precharge contactor. The VCM then opens both.
  3. Check the negative contactors. The VCM closes the positive contactor of both packs alone, with the same check after 100 ms. A voltage now means the negative contactor has welded. The VCM then opens both. Both packs are checked at the same time. With one contactor of each pack closed there is still no closed circuit, so the sense dividers hold V_out near 0 V unless a contactor has welded.
  4. Close everything but the front positive. The VCM closes the rear negative, the rear positive and the front negative. After 50 ms, V_out of the rear pack has to be within 5 V of its V_stack.
  5. Precharge. The VCM closes the precharge contactor. Current flows through the resistor into the DC link, and V_out of the front pack rises toward its V_stack.
  6. Close the front positive. The VCM closes it, waits 50 ms, opens the precharge contactor and waits another 50 ms. V_out of the front pack then has to be within 5 V of its V_stack.

Precharge is complete when both hold:

  • V_stack minus V_out of the front pack is below 10 V, which means less than 1 A through the 10 Ω resistor.
  • V_link from the inverter is within 15 V of the front and rear V_out added together.

Precharge has failed when either holds:

  • V_out of the front pack is below 50 % of its V_stack 100 ms after the precharge contactor closed. A short on the HV bus puts about 40 A, or 16 kW, into the resistor, so this check cuts it short.
  • Precharge is not complete within 500 ms.

After a failed precharge the VCM opens everything. It tries again after 30 s, at most twice. A third failure latches Fault until the next key cycle.

sequenceDiagram
    participant M as VCM main
    participant S as VCM monitor
    participant F as Front BMS
    participant R as Rear BMS
    participant I as Inverter

    M->>F: Command all open
    M->>R: Command all open
    F-->>M: Fast status, no safe power, V_out below 20 V
    R-->>M: Fast status, no safe power, V_out below 20 V
    M->>S: Enable safe power
    S-->>F: Safe power on
    S-->>R: Safe power on
    F-->>M: Safe power seen
    R-->>M: Safe power seen
    M->>F: Close negative only
    M->>R: Close negative only
    F-->>M: V_out below 20 V after 100 ms
    R-->>M: V_out below 20 V after 100 ms
    M->>F: Close positive only
    M->>R: Close positive only
    F-->>M: V_out below 20 V after 100 ms
    R-->>M: V_out below 20 V after 100 ms
    M->>R: Close negative and positive
    M->>F: Close negative
    R-->>M: V_out matches V_stack
    M->>F: Close negative and precharge
    loop Every 10 ms, at most 500 ms
        F-->>M: V_stack, V_out
        I-->>M: V_link on CAN1
    end
    M->>F: Close negative, precharge and positive
    M->>F: Close negative and positive, 50 ms later
    F-->>M: V_out matches V_stack

Opening

A controlled open is used for key off, the end of a charge and the faults the fault table marks as controlled.

  1. The VCM commands zero torque from the inverter and zero current from the OBC.
  2. It waits until the string current is below 5 A, or at most 1 s.
  3. It commands every output open on both BMS in the same frame.
  4. For a key off or the end of a charge, it asks the monitor to release safe power. Both BMS have to report safe power gone within 100 ms. Otherwise the high-side switch is stuck on, which is a fault.

An immediate open skips step 2. The VCM commands every output open in the next frame, whatever the current.

The weld checks run only while closing. After an open, the DC link stays charged until the inverter discharges it, and both V_out dividers sit in series across it, so V_out is not 0 V.

sequenceDiagram
    participant M as VCM main
    participant I as Inverter and OBC
    participant F as Front BMS
    participant R as Rear BMS
    participant S as VCM monitor

    M->>I: Zero torque, zero charge current
    loop Until the current is below 5 A, at most 1 s
        F-->>M: String current
    end
    M->>F: Command all open
    M->>R: Command all open
    M->>S: Release safe power
    S-->>F: Safe power off
    S-->>R: Safe power off
    F-->>M: Safe power gone
    R-->>M: Safe power gone

Measurement disagreement

While the contactors are closed, the VCM compares V_link with the front and rear V_out added together. A difference above 20 V for 1 s means one of the measurements is wrong. The VCM records a fault and keeps the contactors closed, so the car does not lose drive. It refuses the next close until the fault is cleared on a key cycle.

During precharge the same comparison, with the 15 V limit, is part of the completion check. A disagreement there keeps the front positive open and ends as a failed precharge.

Drawings

The battery schematics show the contactors, their coil wiring and the voltage sense leads. The interlock and safe power schematic shows the coil supply from the VCM.